7.18.0.48 Release Notes - 7 November 2024
This guide describes three issues that were fixed in LogRhythm 7.18, as well as the upgrade procedure from 7.18.0 to 7.18.0.48.
The updated components provided in 7.18.0.48 were added to the 7.18.0 GA release downloads on November 7, 2024. If you upgraded using 7.18.0 GA software downloaded after November 7, you do not need to apply this patch.
Resolved Issues
Bug # | Component | Description |
---|---|---|
ENG-62339 * | Client Console | The “Last Log Message” field now correctly displays data as expected in the Deployment Manager - Log Sources screen. |
ENG-62337 | AI Engine | Fixed an issue preventing the AI Engine service from starting after upgrading to LogRhythm SIEM version 7.18. |
ENG-62275 * | Data Indexer | Searches containing greater than 65k terms, including searches that use Lists containing more than 65k items, now successfully execute as expected. |
Issues marked with an asterisk (*) were listed as “Known Issues” on the LogRhythm SIEM 7.18 Release Notes. These Known Issues are now considered resolved.
Download the Upgrade Components
The 7.18.0.48 release includes an updated installer. The new installer can be downloaded from the LogRhythm Community.
Log in to the Community.
On the main menu bar, click Documentation & Downloads, and then click SIEM.
Click NextGen SIEM, and then click 7.18.0 GA Downloads.
Under 7.18.0 GA Downloads, download the LogRhythm Install Wizard.
Upgrade the 7.18.0 Deployment
Run the LogRhythm Install Wizard on the following components/hosts to upgrade a deployment:
AIE/Platform Manager
Data Indexers
If you have not installed the SIEM 7.18.0.46 release from 31 October 2024, the Web Console component should also be upgraded.
For Linux Data Indexers, you will need to download the DX installer and run it on each node.