Skip to main content
Skip table of contents

EVID 1085: Group Policy Extension Failure

Vendor Documentation

Log Fields and Parsing

This section details the log fields available in this log message type, along with values parsed for both LogRhythm Default and LogRhythm Default v2.0 policies. A value of "N/A" (not applicable) means that there is no value parsed for a specified log field.

Log FieldLogRhythm DefaultLogRhythm Default 2.0
ProviderN/A<tag2>
EventID<vmid><vmid>
Version<version>N/A
Level<severity><severity>
TaskN/A<vendorinfo>
OpcodeN/AN/A
KeywordsN/A<result>
TimeCreatedN/AN/A
EventRecordIDN/AN/A
CorrelationN/AN/A
Execution<processid>
<threatid>
N/A
ChannelN/AN/A
Computer<dname>N/A
Security<domain>
<login>
N/A
SupportInfo1N/AN/A
SupportInfo2N/AN/A
ProcessingModeN/A<status>
ProcessingTimeInMilliseconds<milliseconds><milliseconds>
ErrorCode<responsecode><responsecode>
ErrorDescription<subject><subject>
DCName<sname><dname>
ExtensionName<parentprocessname><policy>
ExtensionId<parentprocessid>N/A

Log Processing Settings

This section details log processing changes made from the LogRhythm Default policy to LogRhythm Default v2.0. In some cases, base rules are broken down into sub-rules to appropriately parse log message types by their event types.

LogRhythm Default

Regex ID

Rule Name

Rule Type

Common Event

Classification

1012316EVID 1085: Group Policy Extension FailureBase RuleWindows Group Policy ProblemError

LogRhythm Default v2.0

Regex ID

Rule Name

Rule Type

Common Event

Classification

1012813V 2.0 : EVID 1085: Policy Failed To Be AppliedBase RuleGeneral Warning Log MessageWarning