Add a New Beat in Web Console
Only Global and Restricted Admins can use this feature.
You must initialize the Long-Running LRCTL service to work with Open Collectors and Beats in the Web Console. For instructions on how to initialize the service, see Configure Open Collector Connection to the SIEM.
To add a new Beat:
On the top navigation bar, click the Administration icon, and then click Log Collection.
The Log Sources page appears.On the left side, click Beats.
The Beats page appears.In the upper-right corner of the page, click + New Beat.
The New Beat workflow guides you through two (2) steps as you create your new Beat:
Select Beat Type - the type of Beat from which you want to collect logs.
Configure Beat - configure your Beat.
Select Beat Type
The following Beat types are currently supported in the Web Console:
AWS S3
Azure Event Hub
Carbon Black Cloud
Cisco AMP
Darktrace
Duo Authentication Security
Gmail Message Tracking
GSuite
Kafka
Microsoft Graph API
Okta
Prisma Cloud
Proofpoint
PubSub
Qualys FIM
Sophos Central
Symantec WSS
The first workflow screen prompts you to select the type of Beat you want to create.
Enter text in the search box or scroll through the list to find the Beat type you want to add.
Click the Beat type.
A blue box appears around the selected Beat type.Click Next.
The New Beat workflow advances to the second step and prompts you to configure the Beat.
Configure Beat
The configuration screen appears. Enter the following fields:
General
Field Name | Description |
---|---|
Name | Enter a name for the Beat. |
Open Collector | Select the Open Collector the Beat will be installed on. |
System Monitor Agent | Select the System Monitor Agent that the Open Collector will forward its data to. |
Required
The Required section contains required fields specific to each Beat type. For example, Client ID, API Key, Hostname, or URL Address. For more details on these required fields, see the documentation on how to initialize a specific Beat in Open Collector and Beats.
Throttling
Field Name | Description |
---|---|
Data Limit | Default value = 1000 |
Number of Back Days | Default value = 7 |
Polling Interval
Field Name | Description |
---|---|
Period | Default value = 2 |
After entering the required information and selecting your desired options, click Save.